• Compagnies
  • Contactez-nous
  • English
  • Search icon
Logo Telemac
    • Produits
    • Applications
    • Services
    • Étude de cas
    • Ressources
    • À propos
      • À propos
      • Nouvelles
      • Évenements
      • Contactez-nous
Close icon Close icon Logo Telemac
  • Search icon
    • Produits
    • Applications
    • Services
    • Étude de cas
    • Ressources
    • À propos
      • À propos
      • Nouvelles
      • Évenements
      • Contactez-nous
  • Compagnies
  • Contactez-nous
  • English
  • Logo linkedin
  • Logo youtube
Home » Étude de cas » Pressure Pipe Testing

Pressure Pipe Testing

Publié le 3 mars 2017
  • Facebook Icon
  • Twitter Icon
  • LinkedIn Icon
  • Email Icon

In order to test the feasibility of the method, the tests were performed on a different pipe specimen in a laboratory and on-site

Image Pressure Pipe Testing

 

Short Description:

OXAND Company (France) collaborated with EDF (Electricité de France) on a project regarding the control of ageing of the cooling pipe circuits for nuclear power plants built on the coast. In this context, OXAND proposed non-destructive monitoring of the structural performance using the SOFO system.

Aim of monitoring:

In order to test the feasibility of the method, the tests were performed on a different pipe specimen in a laboratory and on-site. The pipe specimen consisted of three coaxial layers of ordinary concrete, a metallic layer, and reinforced concrete. Different types of artificial damage, simulating the consequences of ageing, were introduced to the specimens, and after pressurisation tests were performed. One long and four short SOFO SMARTapes were installed by gluing them over the
circumference of the artificially damaged cross-section. Each of the four short SMARTapes covered a different quarter of the section making a full ring, while the long SMARTape was installed parallel to the short ones, covering the whole circumference. In addition to SMARTapes, two longitudinal Standard sensors were installed in order to monitor bending and thermocouples were used to control temperature variations. After a test on one specimen was finished, all of the
sensors were successfully uninstalled and reused for other tests. All the data was processed in quasi-real-time using the SOFO Pro and SOFO View software, which displayed the results directly on the Internet in order to make it possible for involved EDF engineers, in different offices around France, to follow the test on-line. 

INSTALLATION PERIODTYPE OF SENSORSNUMBER OF SENSORS
2004SOFO15

Main results:

Average strain measurements performed on the pipe circumference provided reliable data concerning the pipe’s structural behavior and made it possible to simulate ageing damage detection.

Image

View to of the pipe specimen during the test

Image

View of the sensors lay-out

Image

Example of results

Down arrow
fermer

Recherche

En cours...

Logo Roctest

Concepteur et manufacturier d’instrumentation géotechnique, structurale et d’équipements de test pour le sol et la roche

Logo Smartec

Concepteur et manufacturier d’instrumentation géotechnique, structurale et d’équipements de test pour le sol et la roche

Logo Telemac

Founisseur de solutions géotechniques et structurales depuis 1947

Logo Enomfra

Reconnaissance géologique, hydrogéologique
et géotechnique pour les projets les plus variés

Logo Roctest

Concepteur et manufacturier d’instrumentation géotechnique, structurale et d’équipements de test pour le sol et la roche

Logo Smartec

Concepteur et manufacturier d’instrumentation géotechnique, structurale et d’équipements de test pour le sol et la roche

Logo Telemac

Founisseur de solutions géotechniques et structurales depuis 1947

Logo Enomfra

Reconnaissance géologique, hydrogéologique
et géotechnique pour les projets les plus variés

Légal
  • Déclaration de confidentialité
  • Conditions générales de ventes
  • Plan du site
Suivez-nous
  • Logo linkedin
  • Logo youtube
Logo Logo